Since there are few suitable waters for the measurement of radiated noise of underwater targets, most of the measurement tests are carried out in shallow bounded waters,and the measurement results will inevitably be affected by the reflected waves from the interface at the test site,resulting in the deviation of the measured broadband sound pressure level and the sound pressure spectrum level of each frequency. Using the image source method,the numerical simulation of the sound field model in shallow bounded waters is carried out,and the factors that cause the abnormal transmission loss are analyzed. Based on impulse sound technology,a correction method for the measurement results of radiated noise of underwater targets in shallow bounded waters was proposed,and the field tests of radiated noise measurement and transmission loss abnormal value calibration verification were carried out,and finally the measurement results of the test data were corrected.